Format:PG20EP
Liquid
Gas
Steam
This pulse generator is designed to mount on an OVAL flowmeter. The flowmeter,s rotor revolution proportional to the rate of flow is transmitted through a conversion gear train to a permanent magnet which in turn drives a reed switch, Whereby a contact-closure pulse train proportional to the flow rate is generated. This pulse generator is used only for factored pulse generation.
water
kerosene
light oil
Model | PG20EP | |||
---|---|---|---|---|
PG21EP | PG22EP | |||
No. of Pulses per One Pointer Revolution |
1P/rev | 10P/rev | ||
Conversion Gear Ratio | 1/2 | 5/1 | ||
Principle of Signal Generation |
Contact-closure pulses generated by a per-manentmagnet driven reed switch |
|||
Drive Magnet | Material & Property | BF, Anisotropic | ||
Dimensions | 8×5×4 mm | |||
Magnetic Flux Density |
1100 to 1300G | |||
Duty Factor | ON/OFF=1/1 to 1.8/1 | |||
Operating Temp. Range | −20℃ to +90℃ | |||
Finish | Munsell 2.5G 8/2 | |||
Reed Switch Assy. | Part No. | RS−0−13 | ||
Test Volt. across Contact |
125VAC, 50VDC | |||
Current Capacity | 60mA | |||
Contact Bounce | Bounce time: Max. 0.5ms | |||
Life | 10 million Pulses (at 5VA, 60mA Resistance load) 2000 million Pulses (at 12VDC, 5mA Resistance load) |
|||
Contact Protection | w/Surge suppressor and Spark killer. | |||
Finish | Black | |||
Construction | Explosion-proof Construction |
Flame-proof | ||
Explosion-proof Performance |
d2G4 | |||
Conduit Connection | Rc 3/4 | |||
Starting Torque | 25 g•cm Max. at gear ratio 5 to 1 | |||
Suggested Cable | 2-conductor shielded control cable having a conductor area 1.25mm2 to 2.0mm2. Maximum signal cable length 1 km. Shielded cable is suggested only where stray current induction is anticipated; otherwise 2-conductor control cable will do. |
|||
Mass(approx.) | 2.1kg |