//=$_SERVER["REQUEST_URI"] == SRC_ROOT ? 'website': 'article'?>
PRODUCTS
Liquid
Gas
Steam
Format:VXU, VXT, VXW, VXF, VXR, VXJ, VXL, VXM
EX DELTA II - Smart Model has been evolved with the smart functions of various conversion computing, intelligent functions of setting, changing, self-diagnosis, and loop check with calling of range and every factor to be entered. Furthermore, additionally provided communication function utilizing a Smart Communication Unit (EL2310), can execute those operations such as setting and calling of each parameter and also communication with an upper ranked computer. There are two types of sensors, one is fixed type and the other is replaceable type. In the case of the latter, check and replacement are possible without interrupting flow measurement.
More
Liquid
Gas
Steam
With a design to be more usable than ever before, EX DELTA II Battery Powered PAF5 Model operates on an internal battery. In this series, the need of an external power source has been eliminated from the field-proven EX DELTA Ⅱ, which has enjoyed extensive use as a dedicated local monitor, thanks to its all-around characteristics of vortex flowmeter. The display selects variables of the total flow and instantaneous flowrate with an external switch. We also supply models with a separately mounted transmitter to be installed across the field - some located as far as 50 meters from the centralized monitor and control room.
More
Liquid
Gas
Steam
Insertion Type EX DELTA II Smart Model is equipped with an intelligent function that can call up various correction calculations, ranges, and various coefficients, together with functions to set, change and conduct self-diagnosis or loop check. Furthermore, additionally provided communication function utilizing a Smart Communication Unit(EL2310), can execute those operations such as setting and calling of each parameter through communication with a computer. Insertion Type EX DELTA II is available as fixed or hot-tap installation models. The hot-tap installation allows inspection and replacement without interrupting the flow.
More
Liquid
Gas
Steam
Insertion Type EX DELTA II Battery Powered PAF5 Model is dedicated for on-site monitoring with usage in a wide variety of applications. It has been designed to use on the built-in battery alone. The display monitors totalized value or instantaneous flow and the display items can be switched externally. A remote display unit is also available allowing the display to be installed up to 50m away from multiple dispersed sensors. This flowmeter is as fixed or hot-tap installation models
available
More
Liquid
Gas
Steam
Reduced vortex flowmeter with different nominal diameters for the connection and body.
More
Liquid
Gas
Steam
A thermistor sensor picks up the occurrence of vortex caused by the flow velocity change in the manner -- changes in thermistor temperature -- changes in resistance value -- a train of pulses proportional to the flow velocity and measures the flowrate.
Gas purge type is configured to be purged with a clean gas (room temperature) from an external source to the thermistor sensor. Therefore, the fluid to be measured does not touch the thermistor sensor, permitting accurate flow measurement of gases containing dust and mist, low-temperature gases, or others previously thought difficult to be measured.
More
Liquid
Gas
Steam
A thermistor sensor picks up the occurrence of vortex caused by the flow velocity change in the manner -- changes in thermistor temperature -- changes in resistance value -- a train of pulses proportional to the flow velocity and measures the flowrate.
Gas purge type is configured to be purged with a clean gas (room temperature) from an external source to the thermistor sensor. Therefore, the fluid to be measured does not touch the thermistor sensor, permitting accurate flow measurement of gases containing dust and mist, low-temperature gases, or others previously thought difficult to be measured.
More
Liquid
Gas
Steam
A thermistor sensor picks up the occurrence of vortex caused by the flow velocity change in the manner -- changes in thermistor temperature -- changes in resistance value -- a train of pulses proportional to the flow velocity and measures the flowrate.
Gas purge type is configured to be purged with a clean gas (room temperature) from an external source to the thermistor sensor. Therefore, the fluid to be measured does not touch the thermistor sensor, permitting accurate flow measurement of gases containing dust and mist, low-temperature gases, or others previously thought difficult to be measured.
More
Liquid
Gas
Steam
More
Liquid
Gas
Steam
Eggs DELTA II is a Karman vortex flow monitor that is serviceable with liquids and gases. It is suited for consumption control of energy fluid and end-of-line flow management via installation on various equipment. Output-dedicated model without display "Eggs DELTA Pulse" is also available.
More
Liquid
Gas
Steam
More
Liquid
Gas
Steam
Based on the hybrid techniques of combining two different types of sensors -- vortex and thermal -- the Hybrid Multi Delta Flowmeter is an excellent metering tool that can measure an extra-wide range of 1:700 (at 0.6MPa pressure) in one unit. It is best suited for the customer who hopes to manage the consumed amount of compressed air.
More