Insertion Type EX DELTA II Smart Model is equipped with an intelligent function that can call up various correction calculations, ranges, and various coefficients, together with functions to set, change and conduct self-diagnosis or loop check. Furthermore, additionally provided communication function utilizing a Smart Communication Unit(EL2310), can execute those operations such as setting and calling of each parameter through communication with a computer. Insertion Type EX DELTA II is available as fixed or hot-tap installation models. The hot-tap installation allows inspection and replacement without interrupting the flow.
● Offers high accuracy measurement over a wide flowrange.
● Applicable for flow measurement of gas, liquid, and steam.
● Absence of any mechanically moving part on the probe realizes excellent durability.
● Sensor element is designed to be isolated completely from wetted parts and is resistant to dust or mist.
● The 2 wire transmission enables reducing instrumentation cost and simplifying your system.
●Simplified data setting.
● Excellent maintainability improves safety while reducing maintenance costs.
● You can perform maintenance work such as range setting, parameter setting, calibration while installed in the piping.
Model | Insertion type | ||
---|---|---|---|
Nominal size | Wafer type | - | |
Flange type | - | ||
Applicable tube size | 200 to 2000mm | ||
Flow range | Liquid (water) | 72 to 67800m3/h(10 types) | |
Gas (0.2 MPa air) | 923 to 565000m3/h(10 types) | ||
Steam (0.5 MPa saturated steam) | 3.06 to 1790t/h(10 types) | ||
Applicable fluid | Liquid, gas, steam | ||
Operating temp. range | –10 to +300°C | ||
Flange standard | JIS 10K ASME/JPI150 | ||
Max. operating pressure | Depends on flange standard | ||
Accuracy | ±1% of full scale | ||
Power supply | DC-powered or battery-powered | ||
Body material | SUS304 | ||
Configuration | Explosionproof or non-explosionproof | ||
Output | Analog, pulse |