//=$_SERVER["REQUEST_URI"] == SRC_ROOT ? 'website': 'article'?>
PRODUCTS
Format:VXU, VXT, VXW, VXF, VXR, VXJ, VXL, VXM
Liquid
Gas
Steam
EX DELTA II - Smart Model has been evolved with the smart functions of various conversion computing, intelligent functions of setting, changing, self-diagnosis, and loop check with calling of range and every factor to be entered. Furthermore, additionally provided communication function utilizing a Smart Communication Unit (EL2310), can execute those operations such as setting and calling of each parameter and also communication with an upper ranked computer. There are two types of sensors, one is fixed type and the other is replaceable type. In the case of the latter, check and replacement are possible without interrupting flow measurement.
1. Materialization of 2 wires transmission system for cost reduction and simplification of a system to be applied.
2. Ease to data setting.
3. Maintenance cost saving means increase of security operation.
4. Maintenance operation such as range and parameter setting, and calibration can be performed.
Model | Standard | Dia-shaped | ||
---|---|---|---|---|
Nominal size |
Wafer type | 10 to 150mm(15 mm min. for steam) | 15 to 80mm | |
Flange type | 15 to 300mm | 50, 80mm | ||
Applicable tube size | - | - | ||
Flow range |
Fluid (water) | 0.2* to 2510m3/h(11 types) (* Accuracy ±2% FS at 10 mm) |
0.8 to 172m3/h(5 types) | |
Gas (0.2 MPa air) | 2*to 15000m3/h(11 types) (* Accuracy ±2% FS at 10 mm) |
- | ||
Steam (0.5 MPa saturated steam) |
0.02 to 47.6t/h (10 types) (15mm min.) |
- | ||
Applicable fluid | Liquid, gas, steam | Liquid | ||
Operating temp. range | –30 to +300°C –30 to +460°C(For high temperature of replaceable sensor) |
|||
Flange standard | JIS 10, 20, 30K ASME/JPI 150, 300, 600 | |||
Max. operating pressure | 4.51MPa (Depends on flange standard and flange material.) | |||
Accuracy | ±1% of reading or ±1% of full scale | |||
Power supply | DC-powered or battery-powered | |||
Body material | SUS316 or SCS14A | |||
Configuration | Explosionproof or non-explosionproof | |||
Output | Analog, pulse |
*You need to fill out the questionnaire to download documents.
Standard Smart Model