Flowmeters and System Solutions

Flowmeters and System solution.

MENU

PRODUCTS

DENSITY COMPUTER FOR MASS FLOWMETER (WITH SOLIDS PROPORTION CALCULATION FEATURE)

Format:EL4311

In comparison with the previously offered instruments, substantial reduction in physical geometry, improved functions and ease of operation have been achieved. Included among the improvements in this newly developed instrument are simplified parameter changes and data logging with IC cards along with a large, easy-to-read LCD display.
This instrument receives mass flow signal and temperature/ density signals from the OVAL Coriolis flowmeter and, upon calucation, displays the total flow of solids content of pocess fluid that contains solids.
It also can display the corrected density for reference temperature and provide an analog output.

Features
Product Specifications
Document

FEATURES

●Performs calculation of density corrected with temperature.
●Changing the ranges of density, temperature, pressure, or other parameters, of the companion densitometer is simple by keystrokes on the front-panel keypad or by inserting an IC card into the slot.
●A built-in CPU offers a high degree of performance and accuracy.
●Variables such as temperature, pressure, and density can be reviewed on command with the front panel keypad, whether or not computation is in progress.
●A nonvolatile memory (E2PROM) retains all parameters in the event of an ac power failure.
●If an error occurs, its nature is identified as an error message on the display.

GENERAL SPECIFICATIONS

Kinds DENSITY COMPUTER FOR MASS FLOWMETER (WITH SOLIDS PROPORTION CALCULATION FEATURE)
Type EL4311 (For Mass Flowmeter/Solids content flow calculating capability provided)
Power supply for combined flowmeter
Display Density (before and after correction), total flow (mass, solids content flow), instantaneous flowrate (mass, solids content flow), temperature, other
Input signal Flow, density, temperature
Function Scaler, frequency division setting, F/I conversion, temperature correction, communication
Output signal Analog, pulse, alarm
Computation range Temperature –200 to +200°C※1
Density 0 to 6.0000g/mL
Pressure
Computing accuracy Density before correction ±0.001g/mL※2
Density after correction ±0.002g/mL or ±0.006g/mL※2
Temperature ±0.1% of SPAN or ±0.3% of SPAN
Ambient temperature –10 to +50°C
Configuration Non-explosionproof
Power supply AC- or DC-powered

※1: Depends on input signal. Limited in span.

※2: Accuracy with ALTImass and ULTRAmassMK II combined.

Specification

*You need to fill out the questionnaire to download documents.

GEL331E-11

EL4311

Features
Product Specifications
Document
Back

INQUIRY

INQUIRY