Using  the  most  advanced  electronic  technologies,  this digital  instrument  has  been  developed  specifically  to meet  the  most  demanding  steam  flow  measurement applications where accuracy is the prime requirement. 
In response to the gas flowrate, temperature, and pressure information arriving from the sensing terminal, such as  a  flowmeter,  it  calculates  gas  flow,  reduced  to  the equivalent volume flow under standard conditions, and totalizes the flow. 
In addition to meter error curve correction capabilities, a correction factor "X" as a quadratic function of temperature  and  pressure  is  introduced,  giving  you  increased freedom to optimize compensated calculation. 
An  analog  output  and  instant  flowrate  (corrected  for meter error, temperature, and converted to mass) output are additional provisions. With a model dedicated only to flow and pressure inputs, the instrument can also carry out calculations as a pressure compensator with fixed temperature value.
                                  ●By simple key operations or by inserting an IC card in the slot, parameters such as meter factor, temperature and pressure ranges and other parameters in the connected flowmeter can be easily changed.
●Built around a microprocessor, the instrument carries out calculations entirely in digital signal processing circuits to achieve high degree of accuracy and reliability.
●Variables such as temperature and pressure can be reviewed on command with the front panel keypad even during operation.
●A nonvolatile memory (E 2 PROM) retains all parameters and variables. Totalized value can be reset upon power depending on setting.
                                
| Kinds | TEMPERATURE/PRESSURE COMPENSATED GAS FLOW COMPUTER(MASS UNITS) | ||
|---|---|---|---|
| Type | EL4201 (Density mass conversion) | ||
| Power supply for combined flowmeter | 13.5, 24, 32 VDC (depends on combined flowmeter) | ||
| Display | Total flow (before and after correction), total mass flow (after correction), instantaneous flowrate (before correction), instantaneous mass flowrate (after correction), temperature, pressure, etc. | ||
| Input signal | Flowrate (pulse), temperature, pressure | ||
| Function | Scaler, frequency division setting, F/I conversion, instrumental error correction, temperature correction, pressure correction, communication | ||
| Output signal | Analog, pulse, alarm | ||
| Computation range | Temperature | –50 to +350°C (Span limited) | |
| Pressure | 0 to 3 MPa (Span limited) | ||
| Computing accuracy | Total flow after correction | ±0.2% RD or ±0.5%RD | |
| Temperature | ±0.1% of SPAN or ±0.3% of SPAN | ||
| Pressure | ±0.1% of SPAN | ||
| Ambient temperature | –10 to +50°C | ||
| Configuration | Non-explosionproof | ||
| Power supply | AC- or DC-powered | ||