PRODUCTS
Format:UC1
Liquid
Gas
Steam
This flowmeter is a clamp-on type ultrasonic flowmeter for liquids, developed with the concept of 'completely construction-free.' It allows for easy and convenient flow measurement, making it ideal for expanding the measurement range of utility and energy fluids (such as water and hot water) in construction and commercial facilities. By visualizing the flow in every corner of branch pipes, which was previously difficult to implement due to costs and construction periods, it is expected to contribute to energy-saving promotion and decarbonization efforts.
Since it is a clamp-on type that is attached to the outside of the piping, no piping work is required. Maintenance bypass piping is also unnecessary.
One model supports 8 different pipe diameters (nominal diameters: 25A to 100A), from small to large. This is economical because there is no need to stock models corresponding to each pipe diameter for spare parts.
No tools, attachments, or grease are required for installing the flowmeter. It can be fixed to the piping using the two included bands with hand-tightened screws.
It can operate continuously for about 10 years with the built-in battery, so external power equipment and electrical work are not necessary.
water
other
Piping※1 | Nominal size | 25-100A (8 diameters can be measured with one model) |
---|---|---|
Type | Metal pipes (SUS, SGP, etc. under Sch40) and resin pipes (PVC, etc.) in accordance with JIS/ASME standards | |
Lining | None, or polyethylene, vinyl chloride, etc. | |
Metering objects※1 | Type | Liquids in general (hot water, cold water, oils, etc.) |
Temperature range | −20 to +85°C (with derating for operating ambient temperature) | |
Metering system | Ultrasonic wave propagation time difference system(1path) | |
Flow range※2
(Reference flow speed: 0.03 to 10 m/s) |
![]() |
|
Metering accuracy※3,4 | ±3.0% of RD (10 to 100% of max. flow rate), ±0.3% of FS (0.3 to 10% of max. flowrate) | |
Output Select from 2 types |
None
(UC1-MBN) |
No external output |
No-voltage contact output(UC1-MBC) |
・Applied voltage and current:Max. voltage: 26.4VDC, Max. current: 0.25A ・Number of channels:3 channels ・Functions(Set optionally from the functions listed on the right):(1) Normally open, (2) Normally closed, (3) Alarm (output when any of 4 to 10 occurs), (4) Upper limit alarm, (5) Lower limit alarm, (6) Battery voltage reduction, (7) No echo received, (8) Reverse flow, (9) Maximum flow rate exceeded, (10) Accumulated pulse output disabled, (11) Error, (12) Accumulated pulse output (pulse width: 10 to 100ms… Default value: 10 ms) |
|
Operating ambient temperature | −20 to +60°C (key operation below 0°C is not covered by operation guarantee) | |
Protection class | IP65 (available for outdoor use, but direct sunlight must be avoided) | |
Power supply | Dedicated battery (manganese dioxide lithium primary battery)
Battery life: Approx. 10 years(when measuring in stationary position, in energy saving mode, and at an average ambient temperature of 25°C) ※Battery life varies depending on the operating conditions. (the above is not a guaranteed value) |
|
Materials | Housing:Polycarbonate and glass filler (20%)
Fittings:Polyamide (PA66) |
|
Approx. weight | No output: Approx. 450g, No-voltage contact output: Approx. 460g |
※1: Homogenous liquid through which ultrasonic waves propagate and which does not contain a large amount of air bubbles (Measurement may not be possible depending
on the piping material or diameter, or sound velocity of the liquid)
※2: The above flow ranges are reference values for Sch10S size according to JIS G 3459: Stainless Steel Pipes.
The actual flow range varies depending on the inner diameter of the pipe used.
※3: Guaranteed values based on our inspection environment
Errors may occur depending on the type and condition of the customer’s piping, type of fluid, fluid temperature, etc.
※4: Accuracy when electrical noise is applied to the cable (under EN/IEC 61000-4-6 environment of EN/IEC 61326-1) is as follows (only for no-voltage contact pulse
specification). ±6.0% of RD (10 to 100% of max. flow rate), ±0.6% of FS (0.3 to 10% of max. flow rate)
(Note) This product cannot be used in explosionproof areas. In addition, it cannot be used for “transaction and certification” purposes.
Battery-powered Clamp-on Type Ultrasonic Flowmeter for Liquid UC-1
*You need to fill out the questionnaire to download documents.