Ultimate U-shaped flow tube based on the optimized and unified design
Equipped with a sophisticated transmitter (self-diagnosis feature, large size display, and field reconfiguration capability using touch panel), “ALTImass Type U” is an all around high performance Coriolis flowmeter capable of mass flow measurement at a high degree of accuracy. Notable functionality in applications where measurement of extremely low flow, short-duration filling process, etc. together with routine flowrate measurements.
● Zero-point adjustment function (2 methods: Status input by front key operations or adjustment button on the transmitter)
● Error logging function
● Clock function (Accmlated time from power on is saved in the transmitter)
● Factory default parameter reloading function
● Parameter backup function to the display unit
● Status of the flowmeter is presented by two-color backlights (white, orange) and two LEDs (red, green).
● Input signal (sensor) check for disconnection
● Pipeline vibration check
Display screen is large and easy to view with a backlight facilitating setting in a dark place.
●Conventional model
●Type U
Model | CA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050, CA080, CA100, CA150, CA15H, CA200, CA20H, CA250 | ||
---|---|---|---|
Nominal size | 1/4”, 10mm, 15mm, 25mm, 40mm, 50mm, 80mm, 100mm, 150mm, 200mm, 250mm | ||
Process Connection | JIS 10, 20, 30, 40, 63K RF ASME 150, 300, 600 RF, JPI 150, 300, 600 RF DIN PN 10, 16, 25, 40RF, Ferrule, Screw |
||
Acceptable fluids | Liquids, Gases | ||
Flow range | 0 to 2800000kg/h (16 models) | ||
Accuracy | Flowrate | Liquids | ±0.1%RD (CA003 to CA200) ±0.1%RD±Zero stability error (CA20H to CA250, High temperature service model) ±0.2%RD (CA00A, CA001) ±0.2%RD±Zero stability error (High pressure service model) |
Gases | ±0.5%RD±Zero stability error | ||
Density | Liquids | ±0.0005g/mL (CA003 to CA250) ±0.003g/mL (CA00A, CA001, High temperature service model) ±0.004g/mL (High pressure service model) |
|
Temperature range (Differs by explosionproof specification) |
Standard model : −200 to +200℃ (Applicable to all models) | ||
High temperature service model : −40 to +350℃ (CA025 to CA150) | |||
Low temperature service model : −200 to +50℃ (CA025 to CA250) (Explosionproof model) | |||
Max. operating pressure | Depends on flange rating | ||
Wetted materials | SUS 316L, SUS 316L+Alloy C, Alloy CC | ||
Explosionproof specification | TIIS, ATEX, IECEx, KCs, CSA, NEPSI, ITRI | ||
Maritime certification | DNV GL |