Vortex Flowmeter

TOPpage > Product Guide TOP > Flowmeters TOP > Vortex Flowmeter > VF DELTA (Thermistor type)

Categorization by measurement principle
FlowmetersFlowmeters for liquidFlowmeters for gasFlowmeters for steam

VF DELTA (Thermistor type)/Standard type, Gas purge type, Insertion type

General

A thermistor sensor picks up the occurrence of vortex caused by the flow velocity change in the manner -- changes in thermistor temperature -- changes in resistance value -- a train of pulses proportional to the flow velocity and measures the flowrate.
Gas purge type is configured to be purged with a clean gas (room temperature) from external source to the thermistor sensor. Therefore, fluid to be measured does not touch the thermistor sensor, permitting accurate flow measurement of gases containing dust and mist, low temperature gases, or others previously thought difficult to be measured.

Features

• 

Low pressure loss thanks to the absence of moving parts

• 

High maintainability (Replaceable type is available.)

• 

High repeatability

• 

Accurate measurement of gasses containing dust and mist and high and low temperature gases is possible. (Gas purge type)

Standard typeStandard typeStandard type
Gas purge type Insertion type
Insertion type
(For exhaust gas
measurement)
Standard type Gas purge type Insertion type

Major specifications
Model Standard Gas purge type Insertion type
Nominal size Wafer type 20 to 150mm 15 to 150mm
Flange type 200 to 500mm 50 to 500mm
Applicable tube size 200 to 2000mm
Flow
  range
Gas (0.2 MPa air) 3 to 19000m3/h
(12 types)
21 to 19000m3/h
(9 types)
72 to 67800m3/h
(10 types)
Operating temp. range –30 to +130°C
(Depends on body material.)
For room temperature:
–30 to +130°C
–30 to +130°C
(350°C max. for exhaust gas)
For high temperature:
350°C max.
For low temperature:
–200°C min.
Flange standard JIS 10, 20, 30K
ASME 150,300
JIS 10K JIS 10, 20K
ASME 150
Max. operating pressure Depends on flange standard. 0.971MPa 3.04MPa
(Depends on flange standard.)
Accuracy ±1% of reading or ±1% of full scale ±2% of full scale
Applicable fluids Gas
Power supply DC-powered
Configuration Explosionproof or non-explosionproof, IP65 or equivalent
Output Pulse

To General Specification and Catalog Page
Inquiry for this product