Flowmeters and System Solutions

Flowmeters and System solution.

MENU

PRODUCTS

DENSITY COMPUTER FOR MASS FLOWMETER (WITH SOLIDS PROPORTION CALCULATION FEATURE)

Format:EL5310

This digital instrument has been developed to meet the demands for high-precision fluid measurement.

This calculator (or "the instrument") receives mass flow signals from an oval Coriolis flowmeter, along with temperature and density signals. It then calculates and displays the integrated solid content flow rate for fluids containing solid components. Furthermore, it is capable of displaying and analog outputting the corrected density converted to a reference temperature.

Features
Product Specifications

FEATURES

1. Equipped with a large color LCD touch panel, the instrument allows for intuitive parameter setting and operation. It also features a customizable display screen, which helps prevent reading errors by allowing users to hide items not required for inspection.

2. Supporting Modbus communication, the instrument enables reading of various measured values such as integrated values and event logs, as well as writing of various parameters.

3. Various parameters, event logs, and other data stored internally can be easily extracted to a USB memory stick.

GENERAL SPECIFICATION

Kinds DENSITY COMPUTER FOR MASS FLOWMETER (WITH SOLIDS PROPORTION CALCULATION FEATURE)
Type EL5310
Display Density (Before Correction / After Correction),
Mass Integrated Flow, Solid Content Integrated Flow, Mass Instantaneous Flow,
Solid Content Instantaneous Flow, Temperature, etc.
Input Signal Flow, Temperature, Density
Output Signal Pulse, Alarm, Analog
Calculation Range Temperature Resistance Thermometer (Pt100Ω) / Range: −20 to +75℃ 
Analog (4 to 20mADC / 1 to 5VDC) / Range: −20 to +75℃
Analog (10mV/℃) / Range: −50 to +150℃  Standard Span: 200℃
Analog (5mV/℃) / Range: −100 to +200℃ Standard Span: 200℃
Density 0.0000 to 6.0000g/mL
Calculation Accuracy ULTRAmass MKⅡ
(CN series)
Density Before Correction / ±0.001g/mL (Factory Calibration Accuracy: Optional)
Density After Correction / ±0.002g/mL (when temperature input is 4 to 20mADC, 1 to 5VDC),
      ±0.006g/mL (when temperature input is Pt100Ω at 0℃ 3-wire type)※1
Temperature Resistance Thermometer (Pt100Ω): ±0.2℃
Analog (4 to 20mADC / 1 to 5VDC): ±0.1% of SPAN
Analog (10mV/℃): ±0.1% of SPAN
Analog (5mV/℃): ±0.1% of SPAN
Integrated Solid Content ±0.2% of R.D.
Ambient Temperature −10 to +50℃
Power Consumption 20W Max
Power Supply AC or DC Power Supply

※1: Depends on the accuracy of the temperature input and the density expansion coefficient of the fluid relative to the density before correction.
(This shows the accuracy when the density change is constant relative to the difference between the temperature input and the reference temperature.)