Vortex Flowmeter

TOPpage > Product Guide TOP > Flowmeters TOP > Vortex Flowmeter > EX DELTA II

Categorization by measurement principle
FlowmetersFlowmeters for liquidFlowmeters for gasFlowmeters for steam

EX DELTA II/High performance Standard type, Dia-shaped (dirtproof), Insertion type

Fixed sensor type

Replaceable sensor type

Fixed sensor type

Replaceable sensor type

Insertion type

 

Insertion type

 


General

Covering a broad flow and temperature range,
the EX DELTA II measures fluid, gas and steam flows. Its outstanding performance and absence of any moving parts along with its robust and durable yet simple construction makes it suitable for a broad range of applications.

Features

• 

Low pressure loss thanks to the absence of moving parts

• 

Replaceable sensor allows checking and replacing the sensor without stopping the line flow.

• 

High repeatability

• 

Parameter setting and changing, flowrate monitoring, etc. are available through communications. (Smart Type/Smart Communication Unit is required optionally.)

Major specifications
Model Standard Dia-shaped Insertion type

Nominal size

Wafer type 10 to 150mm
(15 mm min. for steam)
15 to 80mm
Flange type 15 to 300mm 50, 80mm
Applicable tube size 200 to 2000mm

Flow
range

Fluid (water) 0.2* to 2510m3/h (11 types)
(* Accuracy ±2% FS at 10 mm)
0.8 to 172m3/h
(5 types)
72 to 67800m3/h
(10 types)
Gas (0.2 MPa air) 2* to 15000m3/h (11 types)
(* Accuracy ±2% FS at 10 mm)
923 to 565000m3/h
(10 types)
Steam (0.5 MPa
  saturated steam)
0.02 to 47.6t/h (10 types)
(15mm min.)
3.06 to 1790t/h
(10 types)
Applicable fluid Liquid, gas, steam Liquid Liquid, gas, steam
Operating temp. range –30 to +300°C
–30 to +460°C
(For high temperature of replaceable sensor)
–10 to +300°C
Flange standard JIS 10, 20, 30K  ASME/JPI 150, 300, 600 JIS 10K  ASME/JPI 150
Max. operating pressure 4.51MPa (Depends on flange standard and flange material.) Depends on flange standard.
Accuracy ±1% of reading or ±1% of full scale ±1% of full scale
Power supply DC-powered or battery-powered
Body material SUS316 or SCS14A SUS304
Configuration Explosionproof or non-explosionproof,
IP66 (DC-powered), IP65 (battery-powered)
Explosionproof or non-explosionproof, IP65
Output Analog, pulse

To General Specification and Catalog Page
Inquiry for this product