SU Series

TOPpage > Product Guide TOP > Electronic Instruments TOP > SU Series > SU1513

Electronic Instruments

SU1513/Pulse Scaler


General

This instrument receives a pulse signal from a flowmeter, etc., shapes it and, after isolation and scaling, supplies two sets of pulse outputs with a desired frequency division and pulse width.

Major specifications
Type SU1513
Power supply for combined instrument 8.5, 13.5, 24, 32 VDC (depends on combined flowmeter)
Input signal Pulse (Current, voltage, open collector, contact)
Max. 3 kHz *1
Output after scaler
  correction
Kinds Open MOS-FET x 2 outputs
Scaler 0.0001 to 1.9999 (settable in 0.0001 steps)
Frequency division 1/1, 1/10, 1/100, 1/1000, 1/10000
Output width 1ms or 50ms
Input synchronization output Open collector pulse
Ambient temperature –10 to +50°C
Configuration Non-explosionproof, non-waterproof
Power supply AC- or DC-powered

*1 : There are limits of capability depending on the combined flowmeter.
*: Scaler setting cannot be set individually for two outputs.
*: For frequency division, two outputs can be set individually.

To General Specification and Catalog Page