//=$_SERVER["REQUEST_URI"] == SRC_ROOT ? 'website': 'article'?>
PRODUCTS
Format:ROU01A, ROU02A, ROU03A, ROU04A, ROU05A, ROU06A, ROU07A, ROU08A, ROU01C, ROU02C, ROU03C, ROU07C, ROU08C, ROU03S, ROU05S
The ROU00 series is a variety of receiving instruments designed for MASFLO-OVAL Ⅱ (thermal mass flowmeter/ controller). Functions necessary for flow measurement/
control are integrated into specialized units. The ROU00 series make possible the easy yet economical configuration of flow measurement/control systems.
1.Small, lightweight, and DIN sized (except for ROU06A) receiving instruments equipped with basic functions necessary for flow measurement/control.
2.External output of 0 to 5VDC is equipped as standard. The upper-grade model ROU00C is equipped with an analog converter, hence compatible with 1 to 5VDC, 0 to 20mADC, and 4 to 20mADC as well.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Flow input / Setting output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC, 0 to 20mADC, 4 to 20mADC (*2) | ||||
External flow output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Min. load resistance: 2kΩ) 0 to 20mADC, 4 to 20mADC (*2) (Max. load resistance: 375Ω) |
||||
External setting input (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Input resistance: 1MΩ) 0 to 20mADC, 4 to 20mADC (*2) (Input resistance: 250Ω) |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 11VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.85kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 6-pin plug for output and input (Model: SNS-1606-PCM-7) (*3) |
(*1): Every signal specification is determined by the specifications of connected MASFLO-OVAL II.
(*2): If analog output of ROU01A is floating current signal and the receiving instrument is not differential input type, an analog isolator must be installed between ROU01A and the receiving instrument. Same principle also applies when the setting device is capable of floating current output.
(*3): Not furnished if special cable (Model: C2-**B) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Flow input | 0 to 5VDC | ||||
External flow output (*1) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 13VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.9kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2) |
(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*2): Not furnished if special cable (Model: C2-**A) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Flow input / Setting output | 0 to 5VDC | ||||
External flow output (*1) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 13VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special res | ||||
Weight | 0.95kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2) |
(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*2): Not furnished if special cable (Model: C2-**A) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Conversion factor setter | Factor setting method: 4-digit digital setter Set-point: 0.500 to 2.000 (*1) |
||||
Flow input | 0 to 5VDC | ||||
External flow output (*2) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 13VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.95kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2) |
(*1): Set-point range may be narrower depending on full scale setting or display scaling.
(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*3): Not furnished if special cable (Model: C2-**A) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Conversion factor setter | Factor setting method: 4-digit digital setter Set-point: 0.500 to 2.000 (*1) |
||||
Flow input / Setting output | 0 to 5VDC | ||||
External flow output (*2) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 13VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.0kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*3) |
(*1): Set-point range may be narrower depending on full scale setting or display scaling.
(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*3): Not furnished if special cable (Model: C2-**A) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Number of connectable unit | 4 units | ||||
Flow input / Setting output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC 0 to 20mADC, 4 to 20mADC (*2) |
||||
External flow output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Min. load resistance: 2kΩ) 0 to 20mADC, 4 to 20mADC (*2) (Max. load resistance: 375Ω) |
||||
External setting input (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Input resistance: 1MΩ) 0 to 20mADC, 4 to 20mADC (*2) (Input resistance: 250Ω) |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 58VA max. | ||||
Installation | Floor or wall mount | ||||
Housing material | Steel sheet | ||||
Weight | 3.5kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3) |
(*1): Every signal specification is determined by the specifications of connected MASFLO-OVAL II. However, signal type of multiple instruments connected to one ROU06A is recommended to be unified.
(*2): If analog output of ROU06A is floating current signal and the receiving instrument is not differential input type, an analog isolator must be installed between ROU06A and the receiving instrument.
Same principle also applies when the setting device is capable of floating current output.
(*3): Depending on the specification of connected instrument, one or two plugs will be furnished. However, plugs will not be furnished if special cable (Model: C2-**I/C2-**O) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Totalizer | Totalizing method: LCD counter (with manual reset) Number of digit: 8 Response frequency: 15Hz max. |
||||
Flow input | 0 to 5VDC | ||||
External flow output (*1) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Pulse output (*2) | Voltage pulse : Low: 0.1V max., High: 5V Response frequency: 3kHz max. Open collector pulse : Pulse width: 25ms (standard) Response frequency: 15kHz max. ON-voltage: 0.8V max. Capacity: 35V/50mA max. |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 16VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.15kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 8-pin plug for output (Model: SNS-1608-PCM-7) (*3) |
(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*2): Two pulse output can be used simultaneously.
(*3): Not furnished if special cable (Model: C2-**C) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Totalizer | Totalizing method: LCD counter (with manual reset) Number of digit: 8 Response frequency: 15Hz max. |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Flow input / Setting output | 0 to 5VDC | ||||
External flow output (*2) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
Pulse output (*2) | Voltage pulse : Low: 0.1V max., High: 5V Response frequency: 3kHz max. Open collector pulse : Pulse width: 25ms (standard) Response frequency: 15Hz max. ON-voltage: 0.8V max. Capacity: 35V/50mA max. |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 16VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.2kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 8-pin plug for output (Model: SNS-1608-PCM-7) (*3) |
(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*2): Two pulse output can be used simultaneously.
(*3): Not furnished if special cable (Model: C2-**C) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Flow input / Setting output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC | ||||
External flow output (*2) | 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ 0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω |
||||
External setting input (*2) | 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ 0 to 20mADC, 4 to 20mADC Input resistance: 250Ω |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 15VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.9kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3) |
(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.
(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.
(*3): Not furnished if special cable (Model: C2-**E) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Flow input (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC | ||||
External flow output (*2) | 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ 0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω |
||||
Power supply, power consumption | 100VAC, 110/115VAC 50/60Hz, 17VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.9kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output (Model: DA-15P-N/DA-C3-J10) (*3) |
(*1): Specifications of flow input is determined by the signal specification of connected MASFLO-OVAL Ⅱ.
(*2): Select one of the signal specifications.
(*3): Not furnished if special cable (Model: C2-**E) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Local/Remote switch | Manual operation, slide switch | ||||
Flow input / Setting output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC | ||||
External flow output (*2) | 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ 0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω |
||||
External setting input (※2) | 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ 0 to 20mADC, 4 to 20mADC Input resistance: 250Ω |
||||
Power supply, power consumption | 100VAC , 110/115VAC 50/60Hz, 17VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.95kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3) |
(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.
(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.
(*3): Not furnished if special cable (Model: C2-**E) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Totalizer | Totalizing method: LCD counter (with manual and remote reset) Number of digit: 8 Response frequency: 15Hz max. Remote reset: “a” contact or open collector, Reset duration: min. 20ms |
||||
Flow input (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC | ||||
External flow output (*2) | 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ 0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω |
||||
Pulse output (*3) | Voltage pulse : Low: 0.1V max., High: 5V Response frequency: 3kHz max. Open collector pulse : Pulse width: 25ms (standard) |
||||
Power supply, power consumption | 100VAC , 110/115VAC 50/60Hz, 18VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.1kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output (Model: DA-15P-N/DA-C3-J10) (*4) |
(*1): Specifications of flow input is determined by the signal specification of connected MASFLO-OVAL II.
(*2): Select one of the signal specifications.
(*3): Two pulse output can be used simultaneously.
(*4): Not furnished if special cable (Model: C2-**F) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Totalizer | Totalizing method: LCD counter (with manual and remote reset) Number of digit: 8 Response frequency: 15Hz max. Remote reset: “a” contact or open collector, Reset duration: min. 20ms |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Local/Remote switch | Manual operation, slide switch | ||||
Flow input / Setting output (*1) | 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC | ||||
External flow output (*2) | 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ 0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω |
||||
Pulse output (*3) | Voltage pulse : Low: 0.1V max., High: 5V Response frequency: 3kHz max. Open collector pulse : Pulse width: 25ms (standard) Response frequency: 15kHz max. ON-voltage: 0.8V max. Capacity: 35V/50mA max. |
||||
External setting input (*2) | 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ 0 to 20mADC, 4 to 20mADC Input resistance: 250Ω |
||||
Power supply, power consumption | 100VAC , 110/115VAC 50/60Hz, 18VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.15kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*4) |
(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.
(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.
(*3): Two pulse output can be used simultaneously.
(*4): Not furnished if special cable (Model: C2-**F) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Flow input / Setting output | 0 to 5VDC | ||||
External flow output (*1) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
External setting input | 0 to 5VDC Input resistance: 1MΩ | ||||
Power supply, power consumption | 100VAC , 110/115VAC 50/60Hz, 13VA max.. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 0.95kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 6-pin plug for input and output (Model: SNS-1606-PCM-7) (*2) |
(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*2): Not furnished if special cable (Model: C2-**G) is included in the order.
Power output | ±15VDC | ||||
---|---|---|---|---|---|
Display | Max. indicator reading: 1999 (3 1/2-digit, Red LED) Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0% |
||||
Set-point adjuster | Setting method: 10 rotary type potentiometer Resistance: 5kΩ ±5% Independent linearity: ±0.2% Mechanical rotation angle: 3600° |
||||
Conversion factor setter | 係数設定方式:Factor setting method: 4-digit digital setter Set-point: 0.500 to 2.000 (*1) |
||||
Flow input / Setting output | 0 to 5VDC | ||||
External flow output (*2) | 0 to 5VDC Min. load resistance: 10kΩ | ||||
External setting input | 0 to 5VDC Input resistance: 1MΩ | ||||
Power supply, power consumption | 100VAC , 110/115VAC 50/60Hz, 13VA max. | ||||
Installation | Panel mount | ||||
Housing material | Special resin | ||||
Weight | 1.0kg | ||||
Accessories | 1: AC power cable, 3m long (with type A plug) 2: 6-pin plug for input and output (Model: SNS-1606-PCM-7) (*3) |
(*1): Set-point range may be narrower depending on full scale setting or display scaling.
(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).
(*3): Not furnished if special cable (Model: C2-**G) is included in the order.
*You need to fill out the questionnaire to download documents.
ROU00 series