Flowmeters and System Solutions

Flowmeters and System solution.

MENU

PRODUCTS

READOUT UNIT for MASFLO-OVAL II MODEL ROU00 series

Format:ROU01A, ROU02A, ROU03A, ROU04A, ROU05A, ROU06A, ROU07A, ROU08A, ROU01C, ROU02C, ROU03C, ROU07C, ROU08C, ROU03S, ROU05S

リードアウトユニット ROU00シリーズ_熱式質量流量計

リードアウトユニット ROU00シリーズ_熱式質量流量計

The ROU00 series is a variety of receiving instruments designed for MASFLO-OVAL Ⅱ (thermal mass flowmeter/ controller). Functions necessary for flow measurement/
control are integrated into specialized units. The ROU00 series make possible the easy yet economical configuration of flow measurement/control systems.

Features
Product Specifications
Document

FEATURES

1.Small, lightweight, and DIN sized (except for ROU06A) receiving instruments equipped with basic functions necessary for flow measurement/control.
2.External output of 0 to 5VDC is equipped as standard. The upper-grade model ROU00C is equipped with an analog converter, hence compatible with 1 to 5VDC, 0 to 20mADC, and 4 to 20mADC as well.

ROU01A (Supplies power to MASFLO-OVAL II. Equipped with flow input/output.)

Power output ±15VDC
Flow input / Setting output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC, 0 to 20mADC, 4 to 20mADC (*2)
External flow output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Min. load resistance: 2kΩ)
0 to 20mADC, 4 to 20mADC (*2) (Max. load resistance: 375Ω)
External setting input (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Input resistance: 1MΩ)
0 to 20mADC, 4 to 20mADC (*2) (Input resistance: 250Ω)
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 11VA max.
Installation Panel mount
Housing material Special resin
Weight 0.85kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 6-pin plug for output and input (Model: SNS-1606-PCM-7) (*3)

(*1): Every signal specification is determined by the specifications of connected MASFLO-OVAL II.

(*2): If analog output of ROU01A is floating current signal and the receiving instrument is not differential input type, an analog isolator must be installed between ROU01A and the receiving instrument. Same principle also applies when the setting device is capable of floating current output.

(*3): Not furnished if special cable (Model: C2-**B) is included in the order.

ROU02A (Equipped with flow display.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Flow input 0 to 5VDC
External flow output (*1) 0 to 5VDC Min. load resistance: 10kΩ
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 13VA max.
Installation Panel mount
Housing material Special resin
Weight 0.9kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2)

(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*2): Not furnished if special cable (Model: C2-**A) is included in the order.

ROU03A(Equipped with flow display and set-point adjuster.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Flow input / Setting output 0 to 5VDC
External flow output (*1) 0 to 5VDC Min. load resistance: 10kΩ
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 13VA max.
Installation Panel mount
Housing material Special res
Weight 0.95kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2)

(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*2): Not furnished if special cable (Model: C2-**A) is included in the order.

ROU04A (Conversion factor setter added to ROU02A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Conversion factor setter Factor setting method: 4-digit digital setter
Set-point: 0.500 to 2.000 (*1)
Flow input 0 to 5VDC
External flow output (*2) 0 to 5VDC Min. load resistance: 10kΩ
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 13VA max.
Installation Panel mount
Housing material Special resin
Weight 0.95kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*2)

(*1): Set-point range may be narrower depending on full scale setting or display scaling.

(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*3): Not furnished if special cable (Model: C2-**A) is included in the order.

ROU05A (Conversion factor setter added to ROU03A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Conversion factor setter Factor setting method: 4-digit digital setter
Set-point: 0.500 to 2.000 (*1)
Flow input / Setting output 0 to 5VDC
External flow output (*2) 0 to 5VDC Min. load resistance: 10kΩ
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 13VA max.
Installation Panel mount
Housing material Special resin
Weight 1.0kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 3-pin plug for output (Model: SNS-1603-PCM-7) (*3)

(*1): Set-point range may be narrower depending on full scale setting or display scaling.

(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*3): Not furnished if special cable (Model: C2-**A) is included in the order.

ROU06A (Provides power to up to 4 MASFLO-OVAL II. Capable of flow input/output.)

Power output ±15VDC
Number of connectable unit 4 units
Flow input / Setting output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC
0 to 20mADC, 4 to 20mADC (*2)
External flow output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Min. load resistance: 2kΩ)
0 to 20mADC, 4 to 20mADC (*2) (Max. load resistance: 375Ω)
External setting input (*1) 0 to 5VDC, 1 to 5VDC, 0 to 10VDC (Input resistance: 1MΩ)
0 to 20mADC, 4 to 20mADC (*2) (Input resistance: 250Ω)
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 58VA max.
Installation Floor or wall mount
Housing material Steel sheet
Weight 3.5kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3)

(*1): Every signal specification is determined by the specifications of connected MASFLO-OVAL II. However, signal type of multiple instruments connected to one ROU06A is recommended to be unified.

(*2): If analog output of ROU06A is floating current signal and the receiving instrument is not differential input type, an analog isolator must be installed between ROU06A and the receiving instrument.
Same principle also applies when the setting device is capable of floating current output.

(*3): Depending on the specification of connected instrument, one or two plugs will be furnished. However, plugs will not be furnished if special cable (Model: C2-**I/C2-**O) is included in the order.

ROU07A (Totalizer and pulse output added to ROU02A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Totalizer Totalizing method: LCD counter (with manual reset)
Number of digit: 8
Response frequency: 15Hz max.
Flow input 0 to 5VDC
External flow output (*1) 0 to 5VDC Min. load resistance: 10kΩ
Pulse output (*2) Voltage pulse : Low: 0.1V max., High: 5V
Response frequency: 3kHz max.
Open collector pulse : Pulse width: 25ms (standard)
Response frequency: 15kHz max.
ON-voltage: 0.8V max.
Capacity: 35V/50mA max.
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 16VA max.
Installation Panel mount
Housing material Special resin
Weight 1.15kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 8-pin plug for output (Model: SNS-1608-PCM-7) (*3)

(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*2): Two pulse output can be used simultaneously.

(*3): Not furnished if special cable (Model: C2-**C) is included in the order.

ROU08A (Totalizer and pulse output added to ROU03A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Totalizer Totalizing method: LCD counter (with manual reset)
Number of digit: 8
Response frequency: 15Hz max.
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Flow input / Setting output 0 to 5VDC
External flow output (*2) 0 to 5VDC Min. load resistance: 10kΩ
Pulse output (*2) Voltage pulse : Low: 0.1V max., High: 5V
Response frequency: 3kHz max.
Open collector pulse : Pulse width: 25ms (standard)
Response frequency: 15Hz max.
ON-voltage: 0.8V max.
Capacity: 35V/50mA max.
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 16VA max.
Installation Panel mount
Housing material Special resin
Weight 1.2kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 8-pin plug for output (Model: SNS-1608-PCM-7) (*3)

(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*2): Two pulse output can be used simultaneously.

(*3): Not furnished if special cable (Model: C2-**C) is included in the order.

ROU01C (Analog signal converter added to ROU01A.)

Power output ±15VDC
Flow input / Setting output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC
External flow output (*2) 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ
0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω
External setting input (*2) 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ
0 to 20mADC, 4 to 20mADC Input resistance: 250Ω
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 15VA max.
Installation Panel mount
Housing material Special resin
Weight 0.9kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3)

(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.

(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.

(*3): Not furnished if special cable (Model: C2-**E) is included in the order.

ROU02C (Analog signal converter added to ROU02A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Flow input (*1) 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC
External flow output (*2) 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ
0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω
Power supply, power consumption 100VAC, 110/115VAC 50/60Hz, 17VA max.
Installation Panel mount
Housing material Special resin
Weight 0.9kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output (Model: DA-15P-N/DA-C3-J10) (*3)

(*1): Specifications of flow input is determined by the signal specification of connected MASFLO-OVAL Ⅱ.

(*2): Select one of the signal specifications.

(*3): Not furnished if special cable (Model: C2-**E) is included in the order.

ROU03C (Analog signal converter and remote control (external setting input) added to ROU03A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Local/Remote switch Manual operation, slide switch
Flow input / Setting output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC
External flow output (*2) 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ
0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω
External setting input (※2) 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ
0 to 20mADC, 4 to 20mADC Input resistance: 250Ω
Power supply, power consumption 100VAC , 110/115VAC 50/60Hz, 17VA max.
Installation Panel mount
Housing material Special resin
Weight 0.95kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*3)

(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.

(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.

(*3): Not furnished if special cable (Model: C2-**E) is included in the order.

ROU07C (Analog signal converter added to ROU07A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Totalizer Totalizing method: LCD counter (with manual and remote reset)
Number of digit: 8
Response frequency: 15Hz max.
Remote reset: “a” contact or open collector, Reset duration: min. 20ms
Flow input (*1) 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC
External flow output (*2) 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ
0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω
Pulse output (*3) Voltage pulse : Low: 0.1V max., High: 5V
Response frequency: 3kHz max.

Open collector pulse : Pulse width: 25ms (standard)
Response frequency: 15kHz max.
ON-voltage: 0.8V max.
Capacity: 35V/50mA max.

Power supply, power consumption 100VAC , 110/115VAC 50/60Hz, 18VA max.
Installation Panel mount
Housing material Special resin
Weight 1.1kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output (Model: DA-15P-N/DA-C3-J10) (*4)

(*1): Specifications of flow input is determined by the signal specification of connected MASFLO-OVAL II.

(*2): Select one of the signal specifications.

(*3): Two pulse output can be used simultaneously.

(*4): Not furnished if special cable (Model: C2-**F) is included in the order.

ROU08C (Analog signal converter and remote control (external setting input) added to ROU08A.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Totalizer Totalizing method: LCD counter (with manual and remote reset)
Number of digit: 8
Response frequency: 15Hz max.
Remote reset: “a” contact or open collector, Reset duration: min. 20ms
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Local/Remote switch Manual operation, slide switch
Flow input / Setting output (*1) 0 to 5VDC, 1 to 5VDC, 0 to 20mADC, 4 to 20mADC
External flow output (*2) 0 to 5VDC, 1 to 5VDC Min. load resistance: 10kΩ
0 to 20mADC, 4 to 20mADC Max. load resistance: 500Ω
Pulse output (*3) Voltage pulse : Low: 0.1V max., High: 5V
Response frequency: 3kHz max.
Open collector pulse : Pulse width: 25ms (standard)
Response frequency: 15kHz max.
ON-voltage: 0.8V max.
Capacity: 35V/50mA max.
External setting input (*2) 0 to 5VDC, 1 to 5VDC, Input resistance: 100kΩ
0 to 20mADC, 4 to 20mADC Input resistance: 250Ω
Power supply, power consumption 100VAC , 110/115VAC 50/60Hz, 18VA max.
Installation Panel mount
Housing material Special resin
Weight 1.15kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 15-pin D-SUB plug for output and input (Model: DA-15P-N/DA-C3-J10) (*4)

(*1): Specifications of flow input and setting output are determined by the signal specification of connected MASFLO-OVAL II.

(*2): Select one of the signal specifications. Signal specifications of external flow output and external setting input do not need to match.

(*3): Two pulse output can be used simultaneously.

(*4): Not furnished if special cable (Model: C2-**F) is included in the order.

ROU03S (Equipped with flow display, set-point adjuster, and external setting input.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Flow input / Setting output 0 to 5VDC
External flow output (*1) 0 to 5VDC Min. load resistance: 10kΩ
External setting input 0 to 5VDC Input resistance: 1MΩ
Power supply, power consumption 100VAC , 110/115VAC 50/60Hz, 13VA max..
Installation Panel mount
Housing material Special resin
Weight 0.95kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 6-pin plug for input and output (Model: SNS-1606-PCM-7) (*2)

(*1): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).

(*2): Not furnished if special cable (Model: C2-**G) is included in the order.

ROU05S (Conversion factor setter added to ROU03S.)

Power output ±15VDC
Display Max. indicator reading: 1999 (3 1/2-digit, Red LED)
Display unit: Direct reading [example: L/min (normal)] or 0 to 100.0%
Set-point adjuster Setting method: 10 rotary type potentiometer
Resistance: 5kΩ ±5%
Independent linearity: ±0.2%
Mechanical rotation angle: 3600°
Conversion factor setter 係数設定方式:Factor setting method: 4-digit digital setter
Set-point: 0.500 to 2.000 (*1)
Flow input / Setting output 0 to 5VDC
External flow output (*2) 0 to 5VDC Min. load resistance: 10kΩ
External setting input 0 to 5VDC Input resistance: 1MΩ
Power supply, power consumption 100VAC , 110/115VAC 50/60Hz, 13VA max.
Installation Panel mount
Housing material Special resin
Weight 1.0kg
Accessories 1: AC power cable, 3m long (with type A plug)
2: 6-pin plug for input and output (Model: SNS-1606-PCM-7) (*3)

(*1): Set-point range may be narrower depending on full scale setting or display scaling.

(*2): Direct output of the signal from the connected MASFLO-OVAL II (0 to 5VDC type only).