Turbine Flowmeter

TOPpage > Product Guide TOP > Flowmeters TOP > Turbine Flowmeter > EX Turbine

Categorization by measurement principle
FlowmetersFlowmeters for liquidFlowmeters for gasFlowmeters for steam

EX Turbine/High accuracy, wide viscosity range

EX Turbine EX Turbine
General

A turbine flowmeter for industry application that allows stable high accuracy measurement for the liquid with a wide range of viscosity including low Reynolds number area. It is suited mainly for petroleum, liquefied gas, and water flowrates.

Features

• 

High accuracy: ±0.2% RD is available.

• 

High accuracy metering is possible even in low Reynolds number area.

• 

Lineup of nominal sizes 15 mm to 400 mm (13 types)

Major specifications
Model Standard type, low viscosity type Standard type, high viscosity type
Nominal size 15 to 50mm 80 to 400mm
Connection JIS 10, 16, 20, 30K Flange, ASME/JPI 150, 300 Flange
Flow range 0.63 to 54m3/h (standard type, 5 types) 10 to 4500m3/h (standard type, 8 types)
Operating temp. range –30 to +120°C (standard, for non-explosionproof type) *
Max. operating pressure 4.51 MPa (depends on connection standard and operating temperature)
Accuracy ±0.2% or ±0.5% of reading
Power supply DC-powered
Body material SUS304, other
Output Analog or pulse
Configuration Explosionproof or non-explosionproof, IP66
Applicable fluids Petroleum, liquefied gas, water, other

*: Flowmeters for high temperature of 350°C max. and for low temperature of -196°C min. are available.

To General Specification and Catalog Page
Inquiry for this product